Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring

Authors

  • Alberto Hernández González Hospital Clínico Quirúrgico "Hermanos Ameijeiras". La Habana
  • Lázaro Edel Sánchez Escalona Hospital Clínico Quirúrgico "Hermanos Ameijeiras". La Habana
  • Caridad de Dios Soler Morejón Hospital Clínico Quirúrgico "Hermanos Ameijeiras". La Habana
  • Mirtha López Ramírez Hospital Clínico Quirúrgico "Hermanos Ameijeiras". La Habana
  • Agustín Mulet Gómez Hospital Clínico Quirúrgico "Hermanos Ameijeiras". La Habana

Keywords:

Tressure transducer, invasive hemodynamic monitoring, transducer calibration

Abstract

Introduction: Transducer calibration is very important for the accurate measurement of pressures during invasive hemodynamic monitoring of patients requiring close observation in the primary care units and in the operating room.
Objective: To develop and validate a method of calibration of pressure transducers, which is simple, efficient and low-cost.
Methods: An alternative manometric method, based on Pascal's law, was developed for the calibration of pressure transducers during invasive hemodynamic monitoring performed at the intensive care unit of the cardiovascular surgery department at Hermanos Ameijeiras Clinical-Surgical Hospital. This method was validated by its comparison with the recommended standard in a total of 215 patients who required invasive hemodynamic monitoring between January and June 2015.
Results: With the alternative manometric method created, the same result was obtained as with the hydraulic method recommended by the literature.
Conclusions: The alternative method created is accurate, efficient and cost-effective.

Downloads

Download data is not yet available.

References

Caballero López A. Terapia Intensiva. Tomo II. La Habana: Editorial Ciencias Médicas; 2007.

Colectivo de Autores. Texto para la especialización de enfermería en cuidados intensivos. Tomo I. La Habana; 2010.

Oliver X, Agelet C. Mecánica de medios continuos para ingenieros. Barcelona: Ed. UPC; 2000.

Lovesio C. Medicina Intensiva. 6ta. ed., Editorial Corpus; 2008.

Published

2017-05-06

How to Cite

1.
Hernández González A, Sánchez Escalona LE, Soler Morejón C de D, López Ramírez M, Mulet Gómez A. Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring. Rev Cub Anest Rean [Internet]. 2017 May 6 [cited 2024 Dec. 22];16(2). Available from: https://revanestesia.sld.cu/index.php/anestRean/article/view/152

Issue

Section

Original articles

Most read articles by the same author(s)